← Home
Enterprise Clients
18+
Named orgs supported
Industries
7
Banking, Tech, Gov, Retail…
Geographies
10+
US, India, EU, AU, APAC
Escalations
25+
Production issues resolved
Severity
P1/P2
Most were production-down

This portfolio documents named enterprise customers whose production issues I directly investigated, root-caused, and resolved as a storage and compute engineer on IBM PowerVC — an OpenStack-based private cloud platform for IBM Power Systems.

A "customer escalation" in this context means the issue was reported from a live production environment, filed through IBM's enterprise support system, and assigned to the engineering team for a code-level fix or targeted patch. Many were P1 (critical production outage) or P2 (major function impaired) severity — requiring fast turnaround and direct customer communication. Customer identities have been generalised to protect confidentiality while preserving the industry, geography, and scale context.

Banking & Financial Services
Large Private Sector Bank (India)
Private sector bank · India · Multiple engagements
  • NetworkFibre Channel port issue preventing VM deployment — FC ports misconfigured, storage database lookup failing
  • NetworkZones deleted incorrectly when using initiator-vfc zoning policy — skip processing if WWPN absent from DB
  • NetworkZone name template truncation for dual initiators in initiator-vfc policy causing connectivity failures
  • StorageFC port configuration page — Fibre Channel ports not discovered in port configuration view
Public Sector Bank (India)
Public sector bank · India · IPG migration issue
  • ComputeVM live migration failure — VMs associated with Initiator Port Groups (IPGs) did not list any eligible destination hosts in migration dialog
Nationalised Bank (India)
Public sector bank · India · Zoning enforcement
  • NetworkStorage template-defined FC ports not being used for zoning with LPAR adapters — platform auto-selecting wrong ports instead of honoring template
  • StorageUnable to map LUN to multiple hosts from a specific server — multipath LUN mapping failure
Major Central Bank (US)
Central bank · United States · Image import failure
  • ImagePost-upgrade image import failure — Python logic bug prevented importing VM images with more than one data volume after upgrade to PowerVC 2.3.2
Commercial Bank (South Africa)
Commercial bank · South Africa · Storage deletion
  • StorageCustomer unable to delete a volume on Hitachi storage — volume stuck in error state, blocked by residual host mappings on the storage array
Technology & Software
Global Technology Company (US)
Technology · United States · Multiple P1/P2 escalations
  • StorageCinder API worker lock contention — Hitachi storage driver holding global lock between API and volume workers causing log pipeline stall (Part 1 & 2)
  • StorageData volumes stuck in "Attaching" state — attach flow not completing, requiring manual state recovery
  • PerfLKU (Live Kernel Update of host OS) with 100 volumes — bulk attach timed out on surrogate partition; attach took longer than SLA
  • StorageIntermittent 503 Service Unavailable errors in storage API calls
  • StorageBulk detach failed with auth connectivity error (keystoneauth1 ConnectFailure)
  • StorageHost mapping visible on storage array while volume shows Available in UI — volume deletion should be blocked until host mapping is cleared
Global Retail Enterprise (Sweden)
Retail / Technology · Sweden · HPE storage issues
  • StorageHPE Alletra storage registration failure — platform unable to register the storage array
  • StorageHPE storage driver missing multipath flag in validate_connection_type() causing single-path connectivity
  • StorageHPE storage in ERROR state with stack traces in cinder-volume logs after registration
  • ImageImage export/import fails on HPE storage — incorrect handling of absent initiator in terminate_connection
European Observability Software Vendor
Observability software · Austria · Upgrade regression
  • ImageVM images stopped working after upgrade from PowerVC 2.2.1.2 to 2.3.1 — regression in image metadata processing caused all image-based deployments to fail
Technology Services Firm (US)
Technology services · United States · Zoning anomaly
  • NetworkZonemanager randomly doubling zone count and paths for a VM when adding a new LUN — race condition in FC zone management caused duplicate zones across storage fabric
Retail & Consumer
Major Fashion Retailer (US)
Fashion retail · United States · Major feature driver
  • StorageDrove the entire Initiator Port Group (IPG) feature implementation — DB schema, API, upgrade scripts, CLI display tool, boot volume tagging, HMC & NovaLink deploy flows, onboard/manage edge cases
  • StorageIPG tag for boot volumes during Storage Connectivity Group creation — ensures correct storage path affinity for IBMi workloads
  • PerfBulk attach SVT script fixes and formatting for high-volume attach test scenarios
Global Beverage Conglomerate (Brazil)
Beverage / FMCG · Brazil · Volume attachment failures
  • StorageVolume detach failure — KeyError in data response from storage connector left volume stuck in detaching state
  • DBVolume attachment interruption left 14 orphaned BDM (block device mapping) entries in database — customer could delete volumes but stale DB records remained, blocking future operations (PowerVC 2.3.2)
Government & Public Sector
Government IT Agency (Australia)
Government IT services · Australia · Multiple deep-dive engagements
  • ComputeVMs deployed with only 50% of expected storage paths — IPG / SPG (Storage Port Group) path allocation halved during VM deployment
  • StorageRemoving a compute host should delete associated Initiator Port Groups — platform leaving empty IPGs behind after host removal
  • Storagemovevdisk retry logic — SVC storage operation intermittently failing, needed retry wrapper
  • StorageReplaced FC port handling in powervc-capture/restore scripts — IPG restore scripts not accounting for WWPN port replacement events
  • StorageAuthored powervc-capture and restore scripts for IPG (Initiator Port Group) backup and recovery
Managed Services & IT Providers
Managed IT Services Provider (US/Europe)
IT services · US & Europe · Multi-release fixes
  • NetworkVM deletion intermittently failing to remove Fibre Channel fabric zones and host objects on storage array
  • ComputeRemote Restart (RR) / Automated Remote Restart (ARR) failing for VMs with IPG enabled — HA restart not honoring port group assignments on 2.1.1 + ifix
IT Solutions Provider (Canada)
IT services · Canada · Stale volume attachment
  • DBDeleted volume still showing as attached to a VM — orphaned attachment record in database after volume deletion, causing inconsistent state visible to customers
Enterprise IT Services Company (Finland)
IT services · Finland · Upgrade documentation gap
  • ImageDocumentation gap: customers not warned to update ALL backup nodes before upgrading to PowerVC 2.3.1 — RPC version mismatch between nodes prevented image imports after partial upgrade
Enterprise & Other
Enterprise Upgrade Customer
Enterprise · Upgrade issue
  • StoragePost-upgrade to PowerVC 2.3.1 — incorrect error message displayed when a storage template is not set on a volume, making diagnosis harder for operators
Financial Services Firm (US)
Financial services · United States · Bulk ops & replication
  • StorageBulk volume detach never completing on IBM PowerVS environment — detach pipeline hung indefinitely
  • StorageAuxiliary volume size change not reflecting after 24 hours — global mirror replication volume sizing out of sync after resize operation
  • StorageGRS (Global Replication Service): Auxiliary volume changes for failover/failback flows
Storage Vendor (POC Engagement)
Storage vendor · VM capture integration
  • ImageVM capture failing with Glance (image service) HTTP 500 error during PowerVC 2.3.0 integration validation for new storage backend
Internal Enterprise Deployments
IBM internal enterprise deployments · Multiple P1 issues
  • ComputeLKU (Live Kernel Update) failures across multiple customer deployments — surrogate LPAR creation failing with mixed NPIV/SSP environments
  • StorageUnable to manage hosts with mixed NPIV and SSP storage connectivity
  • StorageUnable to add IBM Storwize V7000 as pluggable storage provider
  • ComputeCluster state changing to Error / Critical after HMC firmware update
Consumer Products Company (US/PowerVS)
Consumer products · US · PowerVS SRE escalation
  • PerfSlow response to volume detach in IBM PowerVS environment — SRE-reported latency issue in detach pipeline under high concurrency
Generic Enterprise (unnamed field reports)
Multiple enterprise clients · Field-reported production issues
  • StorageVolume page slow to load with large number of volumes — UI refresh performance degradation
  • StorageHitachi storage spinning forever due to bad/expired TLS certificate — no timeout handling
  • ComputeHMC idle session leak — PowerVC leaving open sessions on Hardware Management Console over time
  • StorageStorage connectivity group broken after network change
  • StorageStorage in Error/Critical state — unexplained transition to error after routine operations
  • DBpowervc-dbcheck utility fails to recognize non-zero deleted field values in various database tables
Issue Category Summary
Category What it means Issues
Storage Volume create/attach/detach/delete failures, SAN array driver bugs, host mapping issues 18
Network Fibre Channel zone management, port discovery, path count issues 8
Compute VM lifecycle (deploy, migrate, restart), hypervisor connectivity, host management 7
Image VM image export/import/capture failures, upgrade regressions on image workflows 6
DB Orphaned database records, stale attachment state, consistency checker gaps 4
Perf Bulk operation timeouts, API response latency, attach/detach throughput regressions 4